Vivaldi Ulisse MS6120BTK

Variante codice:Vivaldi Ulisse MS6240BTK
Vivaldi Ulisse MS6060BT 6x60W
Vivaldi Ulisse MS6120BT 6x120W
Multi-zone matrix 6 zones of 120W each with independent music and volumes on each zone.
Selective or general messages via microphone base Vivaldi Ulisse BS6.
Remote zone controls via Vivaldi Ulisse CR1

6x120W multizone amplified matrix with integrated player for listening to WiFi / FM radio / MP3 USB / SD / Bluetooth sources.
IR remote control supplied.
Independent source and volume selection for each zone.
Antenna for FM radio reception.
Vivaldi Ulisse CR1 remote control module with integrated Bluetooth (max 6).
3 MIC/LINE inputs + 1 AUX IN input.
CH1 MP3: WiFi player KEYSOL, BLUETOOTH, TUNER FM, USB, SD CARD zone management via buttons.
CH2-3-4: mic COMBO 5-8mV 600Ω phantom power supply (selectable) / line XLR 150-470mV 10KΩ (switchable).
CH5: RCA AUX input.
CH6 EMC: Priority emergency entry for evacuation or service messages Vivaldi Ulisse GRM1.
* 6 RJ45 outputs for Vivaldi Ulisse CR1 zone commands or Vivaldi Ulisse BS6 multizone microphone bases.
2 monitor outputs with volume control and button (front panel) to select area:
- 6.3mm headphone jack on the front panel.
- RCA for active speakers on the rear panel.
MUTE function.
6 RCA line out: 0.775V (0dBV), each output is controlled by the zone volume.
Speaker outputs 100V, 4-16Ω.
6 zone displays.
Horn terminals: applying a DC voltage of 24V activates the pre-recorded (internal) message for evacuation.
High and low controls on C2, C3, C4, C5 inputs via trimmer.
Power supply AC110-230V, 24Vdc.
Consumption 900VA.
Dimensions 448x88x405 mm (WxHxD).
2U rack.
Weight 8 Kg.
Black cabinet color, orange serigraphs.
Metal cabinet.
Requires Vivaldi Ulisse PSK for rack housing.

* The 6 outputs also support 12 devices by connecting 6 CR1 on the COM02 of the BS6 bases.